5 troubleshooting, General troubleshooting instructions, Table 9 general troubleshooting for flex copy xp – HP StorageWorks XP Remote Web Console Software User Manual

Page 47: 9 general troubleshooting for flex copy xp, 5troubleshooting

Advertising
background image

Flex Copy XP user guide

47

5

Troubleshooting

If you have a problem with the Command View XP computer or the Command View XP or XP Remote

Web Console software, see the HP StorageWorks Command View XP user guide for XP Disk Arrays or

the HP StorageWorks XP Remote Web Console user guide for XP12000/XP10000/SVS200 for

troubleshooting information.
If you need to call you HP account support representative, see ”

Contacting your HP account support

representative

” on page 48 for instructions.

General troubleshooting instructions

Table 9

General troubleshooting for Flex Copy XP

Error

Corrective action

Pair operation cannot be performed from

Command View XP or XP Remote Web

Console (operation is rejected).

React according to the message.

Pair operation cannot be performed from

RAID Manager XP (operation is rejected).

Check the command’s error message, and react according to the

log file and the HP StorageWorks RAID Manager XP user guide.

Pair operation cannot be performed from

RAID Manager XP (operation is rejected) and

the following error message appears:
An order to the control/command device was

rejected.

The following errors are possible. Examine the actual error, and

look for the corresponding error in the following list. Find the part

code and error number, and contact your HP account support

representative for the recommended response.

Factor

Part

code

Error

number

The Flex Copy XP license is not installed.

0605

8500

The Create Pair operation is rejected because

the licensed capacity was exceeded.

8592

The capacities of the selected P-VOL and

S-VOL are not the same.

8519

The specified copy pair does not consist of an

local array volume and the internal LU to

which an external LU is mapped.

8672

The specified volume’s emulation type is not

OPEN-V.

8673

An I/O operation from the host to the

specified P-VOL or S-VOL is in progress.

8675

Copy processing from the S-VOL to the P-VOL

is rejected because the LUN Security XP

Extension S-VOL Disable mode is set to the

P-VOL.

5821

The LUN Security XP Extension S-VOL Disable

mode is set to the S-VOL.

5821

The specified P-VOL is not implemented.

8549

The specified P-VOL is blockaded.

8550

The specified P-VOL is being formatted.

8551

Advertising