Failure of another drive during rebuild, Drive failure in a netware environment, Failed drives or interim recovery mode – HP 60-Modular-Smart-Array User Manual

Page 32

Advertising
background image

Troubleshooting 32

The amount of unused capacity on the drives

The number of drives in the array (for RAID 5 and RAID 6 with ADG)

Allow approximately 15 minutes per gigabyte for the rebuild process to be completed. This figure is

conservative, and newer drive models usually require less time to rebuild.
System performance is affected during the rebuild, and the system is unprotected against further drive

failure until the rebuild has finished. Therefore, replace drives during periods of low activity when

possible.

CAUTION: If the Online LED of the replacement drive stops blinking and the amber Fault LED glows, or if

other drive LEDs in the array go out, the replacement drive has failed and is producing unrecoverable disk

errors. Remove and replace the failed replacement drive.

When automatic data recovery has finished, the Online LED of the replacement drive stops blinking and

begins to glow steadily.

Failure of another drive during rebuild

If a non-correctable read error occurs on another physical drive in the array during the rebuild process,

the Online LED of the replacement drive stops blinking and the rebuild abnormally terminates.
If this situation occurs, reboot the server. The system may temporarily become operational long enough to

allow recovery of unsaved data. In any case, locate the faulty drive, replace it, and restore data from

backup.

Drive failure in a NetWare environment

Use CPQONLIN to identify and monitor drive failure status in a NetWare environment.

Failed drives or interim recovery mode

If a drive fails and hardware fault tolerance is enabled, operation continues. Do the following:

1.

Replace the drive as soon as possible.

2.

Select a logical drive.

3.

Press the F3 key to monitor to the status of drive recovery.

Drive status messages include:

Interim Recovery: The logical drive is operating, but a failed drive has not been replaced.

Replace the drive as soon as possible.

Ready for Recovery: The logical drives are queued for recovery. This status is displayed when

another logical drive is already rebuilding or expanding.

Rebuilding: The array is operating and rebuilding a replacement drive or an online spare, if one

was assigned.

Logical Drive Failed: If you have one or more logical drives that are not protected by fault

tolerance in an array, the data on these logical drives will be lost. ACU shows the logical drives as

FAILED. After drive replacement, any fault-tolerant logical drives rebuild. The logical drives that were

not protected (FAILED) become available for data (the devices are reactivated automatically). If you

have a backup of the data, restore the data now.
If you do not replace the failed drive, the only option, using ACU, is to delete logical drives. Do not

delete logical drives that contain valid data. Doing so results in data loss.

NOTE: A failed status can occur on drives protected by fault tolerance if two or more physical drives fail

concurrently.