Troubleshooting 33

Some status messages are available without pressing the F3 key. For example, on the Main menu, the

FAILED status appears next to the logical drive that has failed. EXPANDING and REBUILDING appear

next to the array in which the activity is occurring.

Handling disk drive failures

If the controller was configured with hardware fault tolerance, complete the following steps after a disk

drive failure:

1.

Determine which physical drive failed. On hot-plug drives, an amber drive failure LED illuminates.

2.

If the unit containing the failed drive does not support hot-plug drives, perform a normal shutdown.

3.

Remove the failed drive and replace it with a drive that is of the same capacity. For hot-plug drives,

after you secure the drive in the bay, the LEDs on the drive each flash once in an alternating pattern

to indicate a successful connection. The online LED flashes, indicating that the controller recognized

the drive replacement and began the recovery process.

4.

Power up the server, if applicable.

5.

The controller reconstructs the information on the new drive, based on information from the

remaining physical drives in the logical drive. While reconstructing the data on hot-plug drives, the

online LED flashes. When the drive rebuild is complete, the online LED is illuminated.

NetWare cannot detect a single physical drive failure when using hardware-based fault tolerance;

NetWare determines that the data is still valid and accessible during the rebuilding process. However, the

driver knows that a physical drive has failed. A message is printed on the console notifying the user that a

physical drive is in a degraded state. CPQONLIN also shows that the drive has failed.