Using hyperterminal for serial communication – AMX VTM-D15/A User Manual

Page 29

Advertising
background image

Configuration and Setup

25

VTM-D15/A 15" MultiMedia Touch Panel Systems

9.

Press F10 to save the changes and exit the Configure page.

10. Select Terminal Emulator from the Communications menu to enter the Communications

Terminal window. Since the ESC key is a legal character in the communications mode, use the

F10 key to exit from this menu option.

Terminal Emulator (Ctrl-t) displays a communications window. Highlighting this option and

pressing ENTER places a "TERMINAL" window on the monitor. The menu bar along the top

of the window provides controls for changing the display and communications options.

11. Type

ECHO ON

(will not appear) and press ENTER. Although there are no characters

displayed, the window is now active and ready to receive commands.

12. Type

HELLO

and press ENTER. This message is used to verify that serial communication has

been established. When a valid connection exists, the device responds with

HOW ARE YOU

DOING.

13. Follow the remaining setup procedures for an Axcess system configuration as listed in the

Setting Up Serial procedures section on page 24. The commands used for AxcessX and

HyperTerminal are the same.

Using HyperTerminal for serial communication

1.

Refer to steps 1 through 4 in the Using AXCESSX for serial communication section on page 24

before beginning communication.

2.

Launch the HyperTerminal program from the Start > Programs > Accessories >

Communications > HyperTerminal folder > Hyperterm.exe.

3.

In the Connection Description dialog box, enter a fictitious name into the Name field.

4.

In the Connect To dialog box, select the COM port being used for communication to the TPI/3.

COM Port Parameter Settings

Parameter

Setting

Bits per second

38,400

Data bits

8 bits

Parity

No parity

Stop bits

1

Flow control

None

• <ASC> - Display (ASCII, Hexadecimal, Decimal)

• F2-Changes the character bits.

• 8 - Character Bits (5, 6, 7, 8)

• F3-Changes the parity.

• N - Parity (E, O, M, S, N)

• F4-Changes the number of stop bits.

• 1 - Stop Bits (1 or 2)

• F9-Opens the Configure menu.

• F1- Changes the display format.

• F10-Returns to the main screen.

The remaining setup instructions must be done after ECHO ON has been entered.