EOTech LWTS Light Weapon Thermal Sight User Manual

Page 63

Advertising
background image

2-45

2.29 UNUSUAL ENVIRONMENT / WEATHER (Continued)

Extreme Heat

The LWTS may exhibit degradation of performance or failure

to operate in temperatures above 120ºF (49ºC). Operating

the LWTS above this temperature may result in the System

Failure Indicator (see section 2.28) appearing on the display.

If due to extreme heat the System Failure Indicator appears,

immediately power down LWTS and allow it to cool below

120˚F (49˚C) before operating. Operating the LWTS for

extended periods in extremely hot temperatures or in direct

sunlight may reduce the reliability and/or service life of the

device.

Salt Air and Sea Spray

After operating in these environments, perform all of the

Inspection / Cleaning procedures described in section

3.2. To prevent corrosion, allow the soft carrying case

to dry thoroughly before placing the imaging system

inside.

Dust Storms and Sand Storms

Blowing sand and dust may damage the optical

surfaces of the LWTS. The objective lens cover should

be installed under these conditions and removed just

prior to operational use.