3.3 CORRECTIVE MAINTENANCE (Continued)

Battery Pack O-Ring Replacement

1. Remove battery pack from the LWTS housing per

section 2.2.

2. If installed, remove batteries from battery pack.
3. Carefully wedge the blade of a small jeweler’s

screwdriver under the battery pack o-ring to lift it up and

out of its retaining groove.

Figure 3-4. Replacing Objective Collar.

4. Apply a few drops of isopropyl alcohol to a cotton swab

and clean the retaining groove of any dirt, grease, or

debris.

5. Apply a thin, even coat of fluorinated grease to the

replacement o-ring.

6. Being careful not to stretch or damage the o-ring, press it

into the retaining groove.

7. If necessary, use a cotton swab to remove any excess

grease from the o-ring and battery pack to prevent

accumulation of debris.