Maintenance and servicing, Section i, Maintenance and troubleshooting – EOTech LWTS Light Weapon Thermal Sight User Manual

Page 65: 1 troubleshooting, Chapter 3 -1, Maintenance and servicing -1, Section i -1, Maintenance and troubleshooting -1, 1 troubleshooting -1, Table 3-1. troubleshooting procedures -1

Advertising
background image

3-1

CHAPTER 3

MAINTENANCE AND SERVICING

SECTION I

MAINTENANCE AND TROUBLESHOOTING

3.1 TROUBLESHOOTING

The procedures below will help correct some of the basic

problems that may arise with the LWTS. If the equipment

malfunction is not listed, or the actions listed do not correct

the fault, refer to section 3.4 for additional guidance.

Table 3-1. Troubleshooting Procedures.

Symptom

Malfunction

Corrective Action

1. No display is

present upon

start-up.

a. LWTS is in Standby

Mode.

a. Press any button to “wake”

from Standby Mode

(section 2.7).

b. Improperly adjusted

settings.

b. Reset LWTS to factory

default parameters

(section 2.8).

c. Software overload.

c. Cycle LWTS power on/off

(section 2.7).

d. Battery power is low or

batteries not properly

installed.

d. Install fresh batteries

(section 2.2).

e. Battery compartment

requires cleaning.

e. Clean battery compartment

(section 3.2).

f. Battery contacts of

battery pack require

cleaning.

f. Clean battery contacts of

battery pack (section 3.2).

Advertising