EXP-06E Access Control System Installation Instruction

Satcom Systems (International) Co., Ltd.

13

7.7.

Configure Alarm Relay
The alarm relay can be activated at the following events:
1. Break In Alarm

This is used to enable the break in signal of door. if the door is opened by
other matters except door opening door release button or present card or
key-in process, the alarm relay will be turned ON and a "alarm occurred"
signal will be stored in memory of the access controller.
p.s. The user must enable the Break In Alarm at the Alarm Section in
Software, and also connect the Door Sensor to the controller.

2. Door Open Alarm

This is used to define the period of door that allows to be opened. The
period can be set from 1 to 99 second. 0 is disabled this function. If the
door is opened out of this period, the alarm relay will be turned ON and a
"alarm occurred" signal will be stored in memory of the access controller.
p.s. The user must input the time (sec) at the Door Open Alarm field in
Software, and also connect the Door Sensor to the controller.

3. Duress Alarm

If the door is opened with key in the duress pin code, the alarm relay will
be turned ON and a "alarm occurred" signal will be stored in memory of
the access controller.
p.s. The user must enable the Duress Alarm jumper(JP8) in the controller
in order to activate this function.

4. Invalid Card & PIN

If the entrance need to input pin code after the card presented, and the
cardholder key in "WRONG CODE" for 7 times continuously. For security
reason, the alarm relay will be turned ON and a "alarm occurred" signal
will be stored in memory of the access controller.

7.8.

Configure Other EXP-06E Options

Watch Dog

:

For keep looking up the event in the controller.
Default is Disable (Open) – JP15.

Duress Alarm :

For activate the alarm when keyin the duress pin code.
Default is Disable (Open) – JP8.

Chain Ending :

For set the controller as the end of the chain

Default is Disable (Open) – JP18.

12V DC

:

For turning ON/OFF the 12V DC input to the controller.
Default is ON (Short) – JP12.

5V/12V DC :

For choosing 5V/12V DC output for card reader. – JP14