EXP-06E Access Control System Installation Instruction

Satcom Systems (International) Co., Ltd.

9

7. INSTALLATION OF EXP-06E


7.1

Overview of EXP-06E


The EXP-06E has two-reader port and one keypad port, capable of handling three
relay outputs. The EXP-06E is housed in a 16 AWG metal wall-mounted cabinet. The
static RAM consumes minimal power for storing memory and data. The EXP-06E is
compatible with PC using Access Control System.

The EXP-06E offers software- controlled features such as Time Zone, Key Zone,
Holiday, Programmable Zone, Cardholders database and Anti-passback control.

The EXP-06E has two types of battery backup: onboard memory and operational
power. The operational power battery, known as the Advanced Power Supply(APS),
gives the EXP-06E internal power fail capability.

7.2 Physical

Requirement

External devices connect to the EXP-06E via ports located on the right and left sides
of the Connectors and the device types are listed in Table 1.1. See Figure 1.1.

The following table is External Devices Connectors

Devices Connectors
In Reader

C1 (1-7)

Out Reader

C3 (1-7)

Keypad C2

(2-8)

Alarm Relay Output

C4 (R,Q)

Programmable Relay Output

C4 (P,O)

Door Lock Relay Output

C4 (N,M)

Door Sensor

C4 (L,K)

Door Release Button

C4 (J,K)

RS-232 Communication Port

C4 (G,H,I)

RS-485 Communication Port

C4 (E,F)

Power Supply DC2, COM

C4 (A,B)

Event Printer Port

C5 PRINTER