APW Wyott VCG User Manual

Page 10

Advertising
background image

10

No heat and conveyor

belts don’t move.

Toaster is installed incorrectly.

Review and perform installation and operation

procedures.

Lid not placed on top securely.

Install or adjust lid so that the push button

plunger on the top of the toaster is depressed.

Manual High Limit switch tripped open.

Reset high limit switch according to the

instructions contained in this manual.

Defective components or wiring problem

Check all connections

No heat and conveyor

belts move.

Temperature Controller

Solid-state relay failure

Check Temperature Controller for an Alarm

Message or erroneous reading. Contact an

authorized APW service technician.

Contact an authorized APW service

technician.

Inoperative Platen or Wiring Problem

Set-point is too low

Contact an authorized APW service agent.

Adjust Temperature Control to desired

setpoint. (See page 6)

Platen is hot and

conveyor belts don’t

move

Product or silicone belt jammed

Turn unit off, disconnect from power, allow to

cool, and and remove silicone belt. Clean

thoroughly according to the instructions in this

manual and re-install the silicone belt.

Wiring problems, loose of broken drive

chains.

Conveyor hung up.

Contact an authorized APW service

technician.

Turn toaster off, wait 5 seconds, and turn

toaster back on. If this happens often, contact

an authorized APW service agent.

Product is over toasted

or heat is too high, or

drop time is too slow,

Bun adjustment controls set incorrectly.

Measure bun thickness and set the bun

controls accordingly.

product is getting stuck

or conveyor belts stop

when

Buns sticking to release sheet.

Clean or replace release sheet or

silicone belt according to the instructions in

this manual.

product is toasting.

Temperature controller set point too high.

Verify thermostat is cycling at the desired

temperature set point and lower if necessary.

Voltage too high.

Verify the line voltage matches the toaster’s

rated voltage identified on the serial number

data plate.

Wiring problems or defective

components.

Contact an authorized APW service

technician.

Product is under toasted

or platen heat is too low

or drop time is too fast

Bun adjustment controls set incorrectly.

Measure bun thickness and set the bun

controls correctly.

Temperature controller set point too low.

Verify that the thermostat is cycling at the

desired temperature and raise if necessary.

Voltage too low.

Verify that the line voltage matches the

toaster’s rated voltage identified on the serial

number data plate

Wiring problem or defective components.

Contact an authorized APW service

technician.

Conveyor belts are

jumping or snapping

Toaster is installed incorrectly

Review and perform installation and operation

instructions.

Conveyor drive belts skipping, loose,

worn, or broken.

Contact an authorized APW service

technician.

Buns getting stuck on

discharge.

Buns not being removed from discharge

chute fast enough. Several buns are

being allowed to collect on the bun chute.

Remove buns from bun chute faster.

Problem

Possible Cause

Corrective Action

Discharge chute has been lifted up and a pan

placed under it (to catch crumbs).

Remove the pan or purchase APW / Wyott

#81699001 BUN CATCHER ACCESSORY KIT.

This part has a pan built in to the bun chute to

catch crumbs.

Advertising