APW Wyott VCG User Manual

Page 11

Advertising
background image



Problem

Possible Cause

Corrective Action

re

Crown and / or heel must

be forced into the toaster.

Toaster is overheating or

cooling fan is not turning

properly.

Toaster making noise or

unusual sounds. (Note that

some noise is inherent to

the normal operation of the

toaster and does not requi

field service. If unsure, call

the APW Wyott technical

service department.)

Temperature Control

Display Error Code – High

Temperature (rly)

Temperature Control

Display Error Code – Probe

or Sensor (prb)

No Temperature Control

Display, or erratic display,

or displays ’---‘

Release sheet and / or silicone belt need

cleaning.

Bun Chute improperly installed.

Dirt and build-up on the fan blades or in the fan

motor.

Drop down side panels rattle.

Lid Rattles

Chains emit squeaking or skipping noise or any

noise indicating metal is rubbing on metal.

Belt wrap pin rubbing on metal housing.

Silicone belt wrap is installed incorrectly.

Failed solid-state relay, heating platen, or

temperature control board.

Loose or “open” sensor, failed sensor.

Unit not plugged in.

Circuit Breakers turned off or tripped.

Wire problem, failed circuit board, or damaged

electrical components

Cooling Fan not turning properly. Control

compartment temperature is above 150° F.

Clean or replace release sheet or silicone belt

according to the instructions in this manual.

Review installation instructions and relocate bun chute.

Verify that the bottom of the bun chute is level and

setting flat on the counter or table.

Turn the unit off, disconnect from power, allow to cool,

and clean the cooling fan blades.

Verify that the door is undamaged, closed and properly

seated on the top cross rods. Verify the silicone belt is

properly installed.
Verify the lid is undamaged, and re-secure it to the top

of the toaster.

Contact an authorized APW technical service

technician.

Center the pin in the belt wrap zipper.

Re-install the silicone belt according to the instructions

in this manual.

Contact an authorized APW service technician.

Contact an authorized APW service technician.

Plug unit in to proper electrical outlet.

Reset breakers. If they trip again, contact your local

electrician or authorized APW service technician.

Contact an authorized APW service technician.

Turn unit off, disconnect power, allow to cool, clean

cooling fan. If toaster continues to overheat, contact an

authorized APW service technician.

Manual Reset Thermostat

The manual reset is a device that provides thermal protection for the platen. In the event that the main

controller or power relay fails to regulate the heat on the platen, the manual reset thermostat will break the

electrical connection to the platen. The control, the motors, the conveyors, and the fans may all continue to

operate, but no more heat will go to the platen. The manual reset thermostat will prevent any power from

going to the platen until a person resets it.

If the manual reset thermostat trips (disallows heat to the platen), this may indicate an extreme failure of

another device. If this thermostat trips more than once, it is important that you contact an authorized APW /

Wyott technical service technician.

To reset the thermostat, locate the thermostat at the rear of the toaster. There is a black knob near the power

cord and the rating label. Unscrew the black cover (you may need a screwdriver). Push in the button that it

is covering. Replace the black cover (hand tight).

Advertising