Operation – APW Wyott VCG User Manual

Page 6

Advertising
background image

$

185

DOWN

UP

MODE

DISPLAY

HEAT ON LED

4. OPERATION

Operating Instructions

Dry operation only

This toaster is for

(no oil). Do not put buttered bread products in the toaster.

Ensure Release sheets are properly installed. (See page 9.)

Turn Main Power Switch on. Set Temperature Control to desired temperature. (Temperature is factory

set at 600°F.) Allow Pilot Light to cycle at least two times (on/off). When the light is on, the grill is heating.

Heat up time is about 15 minutes.

Place bun halves on feeder cut side down (facing grill surface). Toast time is approximately 8, 20 or 30

seconds depending on bun height, diameter and model purchased. Increase or decrease temperature

setting to achieve desired brownness and temperature.

!!
!

OPERATION

1. When power is applied, the digital display will initially show the software version

then change to “Lo”.

2. Press appropriate UP or DOWN switch and then press and hold until desired

setpoint is displayed. Holding the UP or DOWN switch will cause the

setpoint to increment by 1 degree for the first 5 degrees and after that the display

will increment by 5 degrees at a time.

3. Heat On LED will be illuminated until temperature reaches setpoint. Once the

toaster reaches setpoint, the display will change to “rdy” and the Heat on LED will

turn off. The heat on LED will then cycle on and off to maintain temperature.

Bun ThicknessAdjustment
The VSX is designed to accommodate a variety of

different products. Adjust for product thickness by

setting the Bun Adjustment Knobs on the side of the

toaster to the appropriate setting. Settings for

different thicknesses are indicated on the label

adjacent to the adjusting knobs. See photo.

Temperature Control

DIGITAL DISPLAY:

UP SWITCH:

DOWN SWITCH:

HEAT ON LED:

MODE SWITCH:

Shows setpoint, actual

temperature and error / status

messages.

Increase / view setpoint.

Decrease / view setpoint.

Illuminated when power is

being applied to heater.

View actual temperature.

STATUS, ALARM, AND ERROR MESSAGES

Control has reached setpoint and the toaster is ready for operation.

Actual temperature is 50 degrees (or more) below setpoint.

Actual temperature is 50 degrees (or more) above setpoint.

Defective or disconnected temperature probe (sensor).

Appears if relay is defective or inoperable.

rdy

lo

Hi

Prb

HIE

Advertising