General safety InforMatIon

when servicing this unit, verify the power to the unit is turned off prior to opening the control cabinet door.

precautIons

DO NOT USE THIS WATER HEATER IF ANY PART HAS BEEN

UNDER WATER. Immediately call a qualified service technician

to inspect the water heater and to replace any part of the control

system which has been under water.

If the unit is exposed to the following, do not operate heater until all

corrective steps have been made by a qualified service agency.

1. External fire.

2. Damage.

3. Firing without water.

GroundInG InstructIons

This water heater must be grounded in accordance with the National

Electrical Code and/or local codes. These must be followed in all cases.

Failure to ground this water heater properly may also cause erratic

control system operation on ELECTRONIC CONTROL models.

This water heater must be connected to a grounded metal, permanent

wiring system, or an equipment grounding conductor must be run with

the circuit conductors and connected to the equipment grounding

terminal or lead on the water heater.

hydroGen Gas (flaMMable)

Hydrogen gas can be produced in a hot water system served by this heater

that has not been used for a long period of time (generally two weeks or

more). Hydrogen gas is extremely flammable. To reduce the risk of injury

under these conditions, it is recommended that the hot water faucet be

opened for several minutes at the kitchen sink before using any electrical

appliance connected to the hot water system. If hydrogen is present there

will probably be an unusual sound such as air escaping through the pipe

as the water begins to flow. THERE SHOULD BE NO SMOKING OR

OPEN FLAME NEAR THE FAUCET AT THE TIME IT IS OPEN.