Hydraulic system specifications (continued) – AquaStar 32" Channel Drain Pinhole Anti-Entrapment Suction Outlet Cover and Three-Port Manufactured Sump for Vinyl/Fiberglass User Manual

Page 6

Advertising
background image

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940

6

info

@

aquastarpoolproducts.com www.aquastarpoolproducts.com

MANUFACTURED SUMP INSTALLATION (ONE, TWO or THREE PORTS)

IMPORTANT

• Models: 32CDFLxxx, 32 CDAVxxx, 32CDFLVxxx,

32FLACxxx, 32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx, 32CDPHTSxxx
(AV=Anti-Vortex)

• Single or multiple drain or pipe use

• At IAPMO (a nationally recognized

testing lab), all AquaStar channel drains have
been tested to
three inches in sump depth –
field-fabricated or manufactured

• All AquaStar channel drains are

VGB 2008 compliant

• Plumbing to one or two pumps plus skimmer

equalizer are approved – DO NOT exceed
maximum flow rate of outlet cover for total
system

• One-, two- or three-pipe connections are

approved at any port or configuration under
manufactured sump or field-fabricated sump

• Any plumbing configuration is approved but do

not exceed maximum flow rate!

• NOTE: 32CDPHxxx, 32CDPHVxxx, 32CDPHTSxxx

Flow rate is 256 GPM (floor) / 196 GPM (wall)
when more than one port is used.

fig. 1

MANUFACTURED

SUMP INSTALLATION

(ONE, TWO, OR THREE PORTS)

INTERIOR

POOL FINISH

SHOTCRETE / GUNITE

EARTH

GRAVEL

OPTIONAL SINGLE CONNECTION

OR HYDROSTATIC VALVE

2" OR 2-1/2" PIPE

1 PUMP WITH 3" OR 4" TEE

2 SEPARATE PUMP SYSTEM CONNECTIONS

AV STYLE OR FLAT GRATE

(32CDAV) (32CDFL)

SUMP

ALL MODELS LISTED BELOW = ANTI-ENTRAPMENT/ANTI-VORTEX AND

FOR SINGLE OR MULTIPLE USE

MAX FLOW RATES (PER OUTLET) MOUNTING POSITIONS (xxx=COLOR SUFFIX)

Model

32CDFLxxx (and

32CDFLFRxxx,

32CDFLVxxx,

32CDFLACxxx)

32CDLTxxx (and

32CDLTFRxxx,

32CDLTVxxx)

32CDAVxxx (and

32CDAVFRxxx,

32CDAVVxxx,

32CDAVACxxx)

32PDxxx

(min. 2” pipe)

32CDBTxxx,

32CDBTFRxxx

32CDPHxxx (and

32CDPHFRxxx,

32CDPHVxxx,

32CDPHTSxxx)

(min. 2” pipe)

Floor

316 GPM @ 3.9 fps

196 GPM @ 1.3 fps

236 GPM @ 3.4 fps

196 GPM @ 2.3 fps

120 GPM @ 1.2 fps

268 GPM @ 3.1 fps

Wall

208 GPM @ 2.6 fps

192 GPM @ 1.2 fps

136 GPM @ 1.9 fps

88 GPM @ 1.0 fps

N.A.

172 GPM @ 1.0 fps

HYDRAULIC SYSTEM SPECIFICATIONS (continued)

SPECIAL NOTE ON CHANNEL DRAINS TO BUILDER, INSTALLER, PLAN CHECKER AND/OR INSPECTOR!

INSTALLATION LAYOUTS
A. See fig. 1-5 on pages 7-9 for installation layout with manufactured sump.
B. See fig. 6-7 on pages 9-10 for installation layout without sump (field-fabricated sump).
C. Requires phillips screwdriver. Hand tighten only. Do not use electrical or air drills.

D. SPECIAL NOTE

:

USE ONLY PVC TO ABS (transitional glue) for cementing to ABS sump.

Do not use fast set, clear or “hot” blue glues.
E. Measure from underside of high point of the cover to the top of pipe(s) to determine proper sump depth.
F. SPECIAL NOTE : When installing vinyl/fiberglass versions, add a flexible adhesive to fasteners and holes for extra leak

and tamper proofing.