Fig. 5, Important, Fig. 4 – AquaStar 32" Channel Drain Pinhole Anti-Entrapment Suction Outlet Cover and Three-Port Manufactured Sump for Vinyl/Fiberglass User Manual

Page 8

Advertising
background image

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940

8

info

@

aquastarpoolproducts.com www.aquastarpoolproducts.com

MANUFACTURED SUMP INSTALLATION (DUAL PUMP WITH

HYDROSTATIC VALVE INSTALLATION)

fig. 5

MANUFACTURED

SUMP INSTALLATION

(DUAL PUMP WITH HYDROSTATIC VALVE INSTALLATION)

INTERIOR

POOL FINISH

SHOTCRETE / GUNITE

EARTH

GRAVEL

PUMP #2

1-1/2", 2", 2-1/2",

3" OR GREATER PIPE

AV STYLE OR FLAT GRATE

(32CDAV) (32CDFL)

FRAME / MUD-RING

PUMP #1

1-1/2", 2", 2-1/2",

3" OR GREATER PIPE

OPTIONAL HYDROSTATIC VALVE

IMPORTANT

• Models: 32CDFLxxx, 32 CDAVxxx, 32CDFLVxxx,

32FLACxxx, 32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx (AV=Anti-Vortex)

• Single or multiple drain or pipe use

• At IAPMO (a nationally recognized

testing lab), all AquaStar channel drains have
been tested to
three inches in sump depth –
field-fabricated or manufactured

• All AquaStar channel drains are

VGB 2008 compliant

• Plumbing to one or two pumps plus skimmer

equalizer are approved – DO NOT exceed
maximum flow rate of outlet cover for total
system

• One-, two- or three-pipe connections are

approved at any port or configuration under
manufactured sump or field-fabricated sump

• Any plumbing configuration is approved but do

not exceed maximum flow rate

• NOTE: 32CDPHxxx, 32CDPHVxxx, 32CDPHTSxxx

Flow rate is 256 GPM (floor) / 196 GPM (wall)
when in this configuration

IMPORTANT

• Models: 32CDFLxxx, 32 CDAVxxx,

32CDFLVxxx, 32FLACxxx, 32CDAVVxxx,
32CDAVACxxx, 32CDBTxxx, 32CDLTxxx,
32CDLTVxxx, 32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx (AV=Anti-Vortex)

• Single or multiple drain or pipe use

• At IAPMO (a nationally recognized

testing lab), all AquaStar channel drains have
been tested to
three inches in sump depth –
field-fabricated or manufactured

• All AquaStar channel drains are

VGB 2008 compliant

• Plumbing to one or two pumps plus skimmer

equalizer are approved – DO NOT exceed
maximum flow rate of outlet cover for total
system

• One-, two- or three-pipe connections are

approved at any port or configuration under
manufactured sump or field-fabricated sump

• Any plumbing configuration is approved but

do not exceed maximum flow rate

• NOTE: 32CDPHxxx, 32CDPHVxxx,

32CDPHTSxxx Flow rate is 256 GPM (floor) /
196 GPM (wall) when in this configuration

MANUFACTURED SUMP INSTALLATION (BOOSTER & CIRCULATING PUMP INSTALLATION)

For additional information on proper drain installation refer to The Association of Pool &

Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission

Guidelines for Entrapment Hazard.

fig. 4

MANUFACTURED

SUMP INSTALLATION

(BOOSTER & CIRCULATING PUMP INSTALLATION)

INTERIOR

POOL FINISH

SHOTCRETE / GUNITE

EARTH

GRAVEL

BOOSTER PUMP

1-1/2", 2", 2-1/2",

3" OR GREATER PIPE

AV STYLE OR FLAT GRATE

(32CDAV) (32CDFL)

FRAME / MUD-RING

CIRCULATING PUMP

1-1/2", 2", 2-1/2",

3" OR GREATER PIPE

OPTIONAL HYDROSTATIC VALVE

Advertising