Fig. 6, Important, Fig. 7 – AquaStar 32" Channel Drain Pinhole Anti-Entrapment Suction Outlet Cover and Three-Port Manufactured Sump for Vinyl/Fiberglass User Manual

Page 9

Advertising
background image

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940

info

@

aquastarpoolproducts.com www.aquastarpoolproducts.com

9

fig. 6

“A”

2" OR 2-1/2" PIPE

FIELD FABRICATED

SUMP INSTALLATION

(ONE, TWO, OR THREE PORTS)

INTERIOR

POOL FINISH

SHOTCRETE / GUNITE

EARTH

GRAVEL

OPTIONAL SINGLE CONNECTION

OR HYDROSTATIC VALVE

1 PUMP WITH 3" OR 4" TEE

2 SEPARATE PUMP SYSTEM CONNECTIONS

AV STYLE OR FLAT GRATE

(32CDAV) (32CDFL)

FRAME / MUD-RING

IMPORTANT

• Models: 32CDFLFRxxx, 32CDLTFRxxx or

32CDAVFRxxx. 32CDBTFRxxx, 32CDPHFRxxx
(AV=Anti-Vortex)

• Single or multiple drain use

• At IAPMO (a nationally recognized

testing lab), all AquaStar channel drains have
been tested to
three inches in sump depth –
field-fabricated or manufactured

• All AquaStar channel drains are

VGB 2008 compliant

• Plumbing to one or two pumps plus skimmer

equalizer are approved – DO NOT exceed
maximum flow rate of outlet cover for total
system

• One-, two- or three-pipe connections are

approved at any port or configuration under
manufactured sump or field-fabricated sump

• “A” should be a minimum of three (3)inches to

the bottom of cover, must extend the entire
length of the cover.

• Any plumbing configuration is approved but

do not exceed maximum flow rate

• NOTE: 32CDPHFRxxx Flow rate is 256 GPM

(floor) / 196 GPM (wall) when more than one
port is used.

FIELD FABRICATED SUMP INSTALLATION (ONE, TWO or THREE PORTS)

For additional information on proper drain installation refer to The Association of Pool &

Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission

Guidelines for Entrapment Hazard.

fig. 7

"A"

IMPORTANT

* AT IAPMO (A NATIONALLY RECOGNIZED TESTING LAB),

ALL AQUASTAR SUCTION OUTLET COVERS HAVE BEEN TESTED

WITH 3" DEEP SUMPS (UNLESS OTHERWISE INDICATED).

* "A" SHOULD BE A MIN. 3" TO BOTTOM OF COVER.

FIELD FABRICATED

SUMP INSTALLATION

(SINGLE PIPE CONSTRUCTION)

POOL FINISH

INTERIOR

SHOTCRETE / GUNITE

EARTH

GRAVEL

AV STYLE OR FLAT GRATE

(32CDAV) (32CDFL)

FRAME / MUD-RING

SINGLE PIPE CONNECTION

CAN BE ANY SIZE AND ANY

LOCATION ALONG CHANNEL SLOT.

FIELD FABRICATED SUMP INSTALLATION (SINGLE PIPE CONSTRUCTION)

IMPORTANT

• Models: 32CDFLFRxxx, 32CDLTFRxxx,

or 32CDAVFRxxx. 32CDBTFRxxx,
32CDPHFRxxx (AV=Anti-Vortex)

• Single or multiple drain use

• At IAPMO (a nationally recognized

testing lab), all AquaStar Channel
Drains have been tested to 3 inches
in sump depth – field-fabricated or
manufactured

• All AquaStar channel drains are

VGB 2008 compliant

• Plumbing to one or two pumps plus

skimmer equalizer are approved –
DO NOT exceed maximum flow rate
of outlet cover for total system

• One-, two- or three-pipe connections

are approved at any port or
configuration under manufactured
sump or field-fabricated sump

• “A” should be a minimum of three

inches to the bottom of cover

• Any plumbing configuration is

approved but do not exceed
maximum flow rate

For additional information on proper drain installation refer to The Association of Pool &

Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission

Guidelines for Entrapment Hazard.