Important, Fig. 2, Fig. 3 – AquaStar 32" Channel Drain Pinhole Anti-Entrapment Suction Outlet Cover and Three-Port Manufactured Sump for Vinyl/Fiberglass User Manual

Page 7

Advertising
background image

877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940

info

@

aquastarpoolproducts.com www.aquastarpoolproducts.com

7

IMPORTANT

• Models: 32CDFLxxx, 32 CDAVxxx,

32CDFLVxxx, 32FLACxxx,
32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx (AV=Anti-Vortex)

• Single or multiple drain or pipe use

• At IAPMO (a nationally recognized

testing lab), all AquaStar channel
drains have been tested to
three inches in sump depth –
field-fabricated or manufactured

• All AquaStar channel drains are

VGB 2008 compliant

• Plumbing to one or two pumps plus

skimmer equalizer are approved –
DO NOT exceed maximum flow rate
of outlet cover for total system

• One-, two- or three-pipe connections

are approved at any port or
configuration under manufactured
sump or field-fabricated sump

• Any plumbing configuration is

approved but do not exceed
maximum flow rate

MANUFACTURED SUMP INSTALLATION (SINGLE PORT / PUMP INSTALLATION)

For additional information on proper drain installation refer to The Association of Pool &

Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission

Guidelines for Entrapment Hazard.

fig. 2

MANUFACTURED

SUMP INSTALLATION

(SINGLE PORT / PUMP INSTALLATION)

POOL FINISH

INTERIOR

SHOTCRETE / GUNITE

EARTH

GRAVEL

OPTIONAL SINGLE CONNECTION OR HYDROSTATIC VALVE

SINGLE PIPE CONNECTION ON

ANY OF THREE PORTS.

1-1/2", 2", 2-1/2", 3" OR GREATER PIPE

AV STYLE OR FLAT GRATE

(32CDAV) (32CDFL)

FRAME / MUD-RING

PLUG PORTS NOT BEING USED

TO PUMP

MANUFACTURED SUMP INSTALLATION (THREE PORT TEE / SINGLE PUMP INSTALLATION)

IMPORTANT

• Models: 32CDFLxxx, 32 CDAVxxx,

32CDFLVxxx, 32FLACxxx, 32CDAVVxxx,
32CDAVACxxx, 32CDBTxxx, 32CDLTxxx,
32CDLTVxxx, 32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx (AV=Anti-Vortex)

• At IAPMO (a nationally recognized

testing lab), all AquaStar channel drains have
been tested to
three inches in sump depth –
field-fabricated or manufactured

• All AquaStar channel drains are

VGB 2008 compliant

• Plumbing to one or two pumps plus skimmer

equalizer are approved – DO NOT exceed
maximum flow rate of outlet cover for total
system

• One-, two- or three-pipe connections are

approved at any port or configuration under
manufactured sump or field-fabricated sump

• Any plumbing configuration is approved but

do not exceed maximum flow rate

• NOTE: 32CDPHxxx, 32CDPHVxxx,

32CDPHTSxxx Flow rate is 300 GPM (floor) /
168 GPM (wall) when three ports and at least
2 1/2” pipe are used.

fig. 3

MANUFACTURED

SUMP INSTALLATION

(THREE PORT TEE / SINGLE PUMP INSTALLATION)

POOL FINISH

INTERIOR

SHOTCRETE / GUNITE

TEE THREE PORTS TOGETHER

1-1/2", 2", 2-1/2", 3" OR GREATER PIPE

AV STYLE OR FLAT GRATE

(32CDAV) (32CDFL)

FRAME / MUD-RING

TO PUMP

GRAVEL

EARTH

Advertising