FOOD SERVICE EQUIPMENT CO., INC. • 72 Beadel St. • BKLYN • NY 11222

Note: Please see attached

Robertshaw safety pilot

control brochure for

additional guidelines.

4

5. Connect the gas line and check for leaks. Note: air will be trapped in the gas supply lines. This

trapped air will bleed out by holding red button for a few minutes during initial lighting.

6. With the main valve on and the three burner valves off, check for leaks using soapy water or

an electronic leak detector. DO NOT USE OPEN FLAME FOR TESTING.

Burner Valves

in off position;

rotate counter

clockwise to

turn on

Burner Valve in

in on position;

rotate clockwise

to turn off

INITIAL LIGHTING AND SHUT DOWN INSTRUCTIONS

Always follow lighting and shutdown instructions below when operating your unit. A five minute

complete shut-off period is required before lighting or relighting it.

1. With burner valves off, light a match and place in a lighter rod, or use a LP torch. Position the

flame at one pilot burner in the combustion chamber. Hold the red safety button in on the

burner for which you have lit the match or torch. It may take up to 10 minutes to bleed air

trapped in the gas line before the pilot will light.

2. After the pilot lights, remove the match or torch and continue to hold the red safety button for

one minute. After releasing the button the pilot should stay lit. If it does not stay lit, repeat

step 1, but hold button for approximately 90 seconds.

Red safety button

figure (c)

figure (a)

figure (b)