Town Mongolian Barbecue Small User Manual

Page 8

Advertising
background image

FOOD SERVICE EQUIPMENT CO., INC. • 72 Beadel St. • BKLYN • NY 11222

1. With burner valves off, light a match and place it in the lighter rod, or use a torch. Position

the flame at one pilot burner in the combustion chamber. Hold the red safety button in on the

burner for which you have lit the match. It may take up to 10 minutes to bleed air trapped in

the gas line before the pilot will light.

3. The remaining two pilots should light with only a two or three minute bleed time.

4. Turn all three burner valves counterclockwise to “on” position. Observe that each burner has

ignited with a clear, blue flame about 2” long.

5. With burners lit, use a suitable gas leak detector and check for leaks up to the mixer.

6. To shut down, turn burner valves clockwise to off position.

8

LIGHTING AND SHUT DOWN INSTRUCTIONS

Always follow lighting and shutdown instructions below when operating your unit. A five minute

complete shut-off period is required before lighting or relighting.

figure (c)

figure (a)

figure (b)

2. After the pilot lights, continue to hold

the red safety button for one minute.

After releasing the button the pilot

should stay lit. If it does not stay lit,

repeat the above steps in 1.

Red safety button

Burner Valves

in off position;

rotate counter

clockwise to

turn on

Burner Valve in

in on position;

rotate clockwise

to turn off

Note: Please see attached

Robertshaw safety pilot

control brochure for

additional guidelines.

Advertising