Troubleshooting – Cont.

SYMPTOMS

CAUSES

SOLUTIONS

Cannot switch to
computers located on
a slave.

The cables are not

securely fastened.

There is a another slave

cascaded to the first slave.

The slave has more ports

than the master.

The slave is cascaded

from a port other than 1~8
of the master.

Securely reconnect all

cables.

Do not cascade a 3

rd

level

slave to a 2

nd

level slave.

Only one slave per port
can be cascaded from the
master.

Reconfgure the

installation so that the
master always has an
equal number or more
ports than the slave.

Cascade a slave only

from ports 1~8 of the
master.

Verify that the OSD menu

on the master shows a
triangle mark next to the
port that is cascaded.

The switch
occassionally and
irregularly
experiences various
malfunctions.

Insufficient power being

supplied by the connected
computers will result in
power starvation to the
switch.

Connect a 9V DC 500mA

power adapter
(Part #: AD-0950) to the
switch.