Cleanup (cup mode), English – Wagner Power Painter Pro with EZ Tilt User Manual

Page 14

Advertising
background image

English

14

© Wagner Spray Tech. - All Rights Reserved

Cleanup (cup mode)

You will need:

• Waste container
• Cleaner nozzle and lubricant
• Warm soapy water if you sprayed latex materials
• Mineral spirits if you sprayed oil-based materials

Make sure you clean the sprayer in a well-

ventilated area whenever cleaning with

flammable solvents.

The sprayer contains electrical parts. DO nOT

submerge the sprayer into any liquids.

Cleanup (cup mode):

1. Unplug the sprayer. Pour the remaining material back

into the original container.

Rinse the inside of the cup with the appropriate cleaning

solution.

2. Remove the suction tube and filter assembly.
3. Disassemble the suction tube and filter assembly.

note: The threads on the bottom housing (a) are left-

handed. You will need to turn the bottom housing to the

right in order to remove it.

4. Turn the tip nut counter-clockwise and remove the

adjustable spray tip assembly.

Pull the atomizer valve out, being careful not to lose it.
5. Turn the locking nut counterclockwise until it is removed.
6. Slide the pump housing off the sprayer.
7. Remove the spring and piston from the pump assembly.

(continued on next page)

1

2

(a)

3

4

7

5

6

Advertising
This manual is related to the following products: