American Dryer Corp. PHASE 7.2.2 NON-COIN User Manual

Page 14

Advertising
background image

12

0. DRYER SETUP – ALL parameters that pertain to drying are in this menu level.

0. SELECT MODEL – This allows the selection of the heat source applied to the dryer, and whether

the dryer is reversing or non-reversing.

GAS REVERSING

GAS NON-REVERSING

STEAM REVERSING

STEAM NON-REVERSING

ELECTRIC REVERSING

ELECTRIC NON-REVERSING

1. SYSTEM TEMP – This selection controls whether the temperature related programs will be operated

in Fahrenheit (°F) or Celsius (°C). The programs affected are as follows:

1) Temperature Display Mode

2) Drying Temperatures

3) Cool Down Temperatures

IMPORTANT: The Phase 7 non-coin microprocessor controller (computer) automatically calculates

and converts the temperatures in these programs to the previously set value. For
example, when changing from °F to °C, if the preprogrammed Cycle “A” drying
temperature was set for 160° F, the Phase 7 non-coin microprocessor controller
(computer) will change to 71° C (+/- 1° Celsius).

2. ENTER LINT CLEANING FREQUENCY 1 TO 10 HOURS – This selection sets how long the

lint cleaning timer will run before prompting the user to “CLEAN LINT”. Once the user is prompted
to “CLEAN LINT”, the Phase 7 non-coin microprocessor controller (computer) will allow an
additional 2 hours of run time before the dryer is placed into a locked-out state, waiting for the lint
drawer to be cleaned.

3. ENTER AUDIO ALERT ON TIMES 0 TO 10 – This selection allows the operator to adjust the

amount of signal tones. This parameter (program) affects the tone at the end of the Cool Down
Cycle, as well as at the end of the Wrinkle Guard On Time.

4. ROTATION SENSOR – This selection is used to turn the rotational sensor on or off.

5. BOARD ADDRESS 00 TO ZZ – This location is where the board address is defined. This is only

used when the Phase 7 non-coin microprocessor controller (computer) is interfaced to a network.

6. AUTO CYCLE TIME OUT 0 TO 99 MINUTES – This selection allows the user to set a maximum

time that the auto cycle will run before timing out.