American Dryer Corp. PHASE 7.2.2 NON-COIN User Manual

Page 17

Advertising
background image

15

6) Once the Cool Down Cycle begins at the end of the heat cycle, the light emitting diode (L.E.D.)

display will read COOL DOWN TEMP ___/___ MINUTES REMAINING. At the end of the
heat cycle, the dryer will shut off the heat and continue the fan and basket (tumbler) until the Cool
Down Time or temperature is reached.

7) Once the Cool Down Cycle is completed, the Phase 7 non-coin microprocessor controller (computer)

will proceed into the Wrinkle Guard Cycle. The Audio Alert tone will sound (for the amount set in
Audio Alert On Time). The L.E.D. display will read “CYCLE DONE”. The dryer will wait an
initial 15 minutes delay before going into a 15-seconds ON, 5 minutes OFF cycle. These times are
fixed and are not programmable. During the ON Time, the blower (fan) and the basket (tumbler)
will start to rotate without heat for 15-seconds; during this time, the display will read “WRINKLE
GUARD”. After the 15-seconds are completed, the display will read “CYCLE DONE” and the
dryer will go into a 5 minute OFF cycle. The Phase 7 non-coin microprocessor controller (computer)
will repeat this process of 15-seconds “ON” and 5 minutes “OFF” until either the doors are opened,
the “STOP/CLEAR” key is pressed, or 99 minutes have elapsed, whichever comes first. Once
the 99 minutes have elapsed, the L.E.D. display will then read “CYCLE DONE” and the Phase 7
non-coin microprocessor controller (computer) will lock out the dryer functions until the doors are
opened. The Phase 7 non-coin microprocessor controller (computer) will then return to “READY”.

b. Timed (Manual) Drying Cycle

1) L.E.D. display reads “READY” (no cycle in progress).

2) Press the letter on the keyboard (touch pad) corresponding to the cycle desired (i.e., key “D”).

NOTE: “0-40” WILL REQUIRE THE “START/ENTER” KEY TO BE PRESSED AFTER THE

NUMBER IS SELECTED IN ORDER TO ACCEPT THE SELECTION and START
DRYING.

3) The dryer will then start. (I.E., blower, basket [tumbler], and heat).

4) The L.E.D. display will read MANUAL DRYING CYCLE D, 00:00 MIN REMAIN.

NOTE: Press and hold the “UP ARROW” to view the basket (tumbler) temperature at any time.

NOTE: The dryer can be stopped at any time by pressing the “STOP/CLEAR” key, at this time the

dryer will go into a cycle pause. If the “STOP/CLEAR” key is pressed again at this point,
the cycle that was in progress will be cancelled and returned to the “READY” state.

NOTE: Press and hold the “DOWN ARROW” to view the basket (tumbler) RPM.

5) When the programmed drying time has expired, the Phase 7 non-coin microprocessor controller

(computer) will proceed into the Cool Down Cycle.

6) Once the Cool Down Cycle begins at the end of the heat cycle, the L.E.D. display will read COOL

DOWN TEMP ___/___ MINUTES REMAINING. At the end of the heat cycle, the dryer will
shut off the heat and continue the fan and basket (tumbler) until the Cool Down Time or temperature
is reached.

Advertising