3-7. Inverter Operation

To operate the power inverter, turn it on by using the ON/OFF switch on the

front panel. The power inverter is now ready to deliver AC power to your

loads. If you are operating several loads from the power inverter, turn them

on separately after the inverter has been turned on.

This will ensure that the power inverter does not have to deliver the starting

currents for all the loads at once.

3-7-1. Unpack and inspect the power inverter, check to see that the power

switch in the OFF position.

3-7-2. Connect the cables to the power input terminals on the year panel of

power inverter.

The terminal is positive (+) and black terminal is negative (-).

Insert the cables into the terminals and tighten allen nut to clamp the

wires securely.

3-7-3. Before proceeding further, carefully check that cable you have just

connected does tie negative terminal of inverter to the negative output

power source.

3-7-4. Connect the cable from the negative terminal of the inverter to the

negative terminal of the power source. Make a secure connection.

WARNING!
Reverse polarity connection will blow a fuse in inverter

and may permanently damage the inverter.

Damage caused by reverse polarity connection is not

covered by warranty.

WARNING!
Make sure all the DC connections are tight (torque to

9-10 ft-lbs, 11.7-13Nm). Loose connections will

overheat and could result in a potential hazard.