3-1-4. Battery Voltage indicator

The AC load watt bar graph indicates the power drawn from the power

inverter by the load. For long term operation, the watt indicator

should remind in the green & orange area of the bar graph.

Short term operation is possible with watt indicator in the red area.

If the watt indicator rises to high values the bar will flash and the

inverter will shutdown to protect itself.

3-1-5. OVP : Over Voltage indicator

The over voltage indicator indicates that the power inverter has shut

itself down because its input voltage exceeded 12 / 24 VDC version.

3-1-6. UVP : Under Voltage Protection indicator

The under voltage indicator indicates that the power inverter has shut

itself down because its input voltage fell below 12 / 24 VDC.

3-1-7. OTP : Over Temperature Protection indicator

The over temp indicator indicates that the power inverter has shut itself

down because its temp has become overheated. The power inverter

may overheat because it has been operated at power levels above its

rating, or because it has been installed in a location which does not

allow it to dissipate heat properly. The power inverter will restart

automatically, once it has cooled off.

3-1-8. OLP : Over Load Protection indicator

The overload indicator indicates that the power inverter has shut itself

down because its output has been short circuited or drastically

overloaded.

Switch the ON/OFF switch to OFF, correct the fault condition, and then

switch the ON/OFF switch back to ON to reset the unit.

3-1-9. Power Saving: Power energy saving enable.

See appendix 9-2 for detailed information.

3-1-10. AC Outlet (Outlet sockets available):