8-2-2-2. Command format

This unit supports the following commands.

There should always be a CR (0DH) and a LF (0AH)

appended to the command while sending the command to his

unit.

8-2-2-3. PWRS command

Power saving function control
Format

: PWRS < value>

Illustration

:A space (ASCll code 20H) is needed between

PWRS and < value >

< value > can be one of the following
“0”

:Power saving disable

“1”

:Power saving enable

“2”

:Inquire the status of saving the response information

would be either “0” (disable) or “1” (enable)

8-2-2-4. Power command

Power ON/OFF control
Format

:Power < value>

Illustration

:A space (ASCll code 20H) is needed between

PWRS and < value >

< value > can be one of the following
“0”

:Power off, power consumption < 2W, restart time < 5 sec

“1”

:Power off, power consumption <20W, restart time < 2

sec

“2”

:Power on

“3”

:Inquire the status of power on/off status, the response

information would be either “0” (OFF) or “1” (OFF) or “2”

(ON)