9-2-6. Power saving “sleep” mode, disabled

9-2-6-1. The front plate has a green led marked “power saving” for

indication of enable state of power save “sleep” mode (here-

in-after referred to as the green led).

9-2-6-2. The power saving “sleep” mode is disabled when the green

led marked “power saving” is off. In this mode the output

power is always available.

9-2-6-3. Following indications will be observed when the inverter is

powered on and subsequently loaded and unloaded when

power saving “sleep” mode is in disabled condition: (the initial

condition is that the inverter is switched off and all loads are

disconnected).

9-2-6-3-1. Switch on the inverter. There will be 2 beeps and

green led will start flashing with a flashing

sequence of flash-flash-flash… After about 3

seconds, there will be 1 beep and the green led

will stop flashing and switch off. Output power will

be available after about 15 to 18 sec from the time

the green led switches off. The output power will

be always available, even in no load idling

condition.

The green led will be off all the time.

9-2-7. Switching between enabled and disabled states of power saving

“sleep” mode

9-2-7-1. Switching between enabled and disabled states of power

saving “sleep” mode can be done with the help of the power

on / off switch on the front plate of the inverter or with the help

of the optional remote control.

Switch on the front plate of the inverter is done as follows: