9-2-4-2. The power saving “sleep” mode is enabled in either of the

following indications (When inverter is in on condition):

The green led flashing sequence is:

Flash-flash-gap-flash-flash-gap… (power saving “sleep”

mode, idle condition or no load) .

The green led is continuously lighted (power saving “sleep”

mode, loaded).

9-2-5. Following indications will be observed when the inverter is powered on

and subsequently loaded and unloaded when power saving “sleep”

mode is in enabled condition: (the initial condition is that the inverter is

switched off and all loads are disconnected).
9-2-5-1. Switch on the inverter. There will be 2 beeps and the green

led will start flashing with a flashing sequence of flash-flash-

flash… After about 3 seconds, there will be 1 beep, the green

led will stop flashing and it will be lighted continuously.

Output power will be available after about 15 to 18 sec from

the time the green led stops flashing. After the output power

is made available, the inverter searches if any load is

connected. If the load is less than 2 to 15 watts, the output

power is shut down after about 15 seconds from the time the

output power is made available.

The green led will start a flashing sequence of flash-flash-

gap-flash-flash-gap… (this indicates that the inverter is in

power saving “sleep” mode and is idling at no load).

9-2-5-2. If now a load more than 2 to 15 watts is switched on, the

green led stops flashing after about 3 seconds and will be

lighted continuously. After about 15 to 18 seconds after the

green led has stopped flashing and become steady, output

power will be available to the load. The green led will be

lighted continuously (this indicates that the inverter is in

power saving “sleep” mode and is in loaded condition).

9-2-5-3. If the load is switched off, the output power will be shut down

after about 15 to 18 seconds and the green led will start

flashing with a flashing sequence of flash-flash-gap-flash-

flash-gap…(this indicates that the inverter is in power saving

“sleep” mode and is idling at no load).