Appendix C. Log Files and the LogTool Application

TABLE C-1. Transaction Log Messages

Code

Message Text

Message Parameters

Message Meaning

User Response to
Message

14 Clock

check

failed

Reason code:
3. Communication failure
4. Invalid datalogger
security clearance
5. Invalid transaction
number specified (already
in use)
6. Communications are
disabled for this device
7. The transaction was
aborted by client request
8. The device is busy with
another transaction

The clock check/set
failed for the reason
specified in the
reason code.

Check the connections
of the communication
path to the datalogger,
make sure the
datalogger is connected
and has power, check
the security setting in
the datalogger and in
Setup, check that
communications are
enabled in Setup for all
the devices in the path.

26 Data

polling

started

Data collection by
polling started.

27

Data polling
complete

Data collection by
polling completed

28

Data polling
failed

Data collection by
polling failed due to
communication
failure or a timeout.

Check communications
with the datalogger by
trying to check the
clock. If that fails,
follow the steps for
message 14.

29

Directed data
query start

A user initiated query
has been started.

30

Directed data
query continue

The requested data in
the directed query
could not fit in one
block and the next
part is being
requested.

31

Directed data
query complete

The

user

requested

data has been
received by the
server.

32

Directed data
query failed

The directed query
request failed.

33

Getting logger
table definitions

The server is getting
the table definitions
from the datalogger.

Getting the datalogger
table definitions will
erase any data in the
data cache.

34

Received logger
table definitions

The

server

has

received the
datalogger table
definitions.

35

Failed to get
logger table
definitions

The request to get
table definitions has
failed.

C-4