Section 5. Split

Blanks and Count are functions designed for checking the
integrity of the data file. A common use for these two functions
is “100.*BLANKS(x;n)/BLANKS(x;n)+COUNT(x;n)” which
gives the percentage of holes (bad data) in the file.

NOTE

Max(x;n)

returns the maximum value of element x over a full data set
or every n

th

value.

Examples:

Max(5)

= 17.12 (max WS for day)

Max(5;12) = 10.41 (max WS for 12 hours)

17.12 (max WS for 12 hours)

Min(x;n)

returns the minimum value of element x over a full data set
or every n

th

value.

Examples:

Min(7)

= 4.23 (min std. dev. of WS for day)

Min(3;8) = 55.33 (min temp for 8 hours)

59.79 (min temp for 8 hours)

55.22 (min temp for 8 hours)

RunTotal(x;n) returns a running total of element x for every line in the data

set. If an n

th

value is specified, a running total will be output

every n

th

value.

Example:

RunTotal(5)

=

5.85

14.12

21.87

29.47

39.88

48.87

:

:

:

166.76

182.38

199.50

211.36

211.36

Running total of hourly average wind speed provides up-to-
the-hour wind run for that day. Because an n

th

value was not

specified, the Final Summary output, which is daily wind, is
the same as the “total” output.

Sd(x;n)

returns the standard deviation of element x over a full data
set or every n

th

value.

Examples:

Sd(3) = 3.6593 (std. dev. temp for day)

Sd(3;8) = 1.011 (Sd temp for 8 hours)

1.1182 (Sd temp for 8 hours)

4.965 (Sd temp for 8 hours)