AVE Video Serial Synchronous ATM Interface VSSI-PRO User Manual

Page 39

Advertising
background image

39

PROGRAMMING THE VSSI-PRO

VSSI-Pro VIDEO SERIAL ATM INTERFACE

NOTE

"

"

"

"

"

2 Exception Strings, Nos. 23 & 24, are preprogrammed for beginning and ending trans-
actions and with DISPLAY off. The display messages for these two exceptions are “TRANS-
ACTION BEGIN” and “TRANSACTION END,” which means that when a transaction starts,
an on-screen alarm is triggered and the “TRANSACTION
BEGIN” message will be sent out
but not displayed, and the same will occur at the end of a transaction. You can display
either of these messages by turning DISPLAY for these numbers “ON”.

To program the Triggered Text, go to the ALARM OUTPUTS sub-menu. Select the desired ALARM NO, then go to the
TRIGGERED TEXT sub-menu. The DISPLAY and OUTPUT TEXT menu entries are self explanatory. Select the third entry
to program the TRIGGERED TEXT. When this entry is selected, the currently programmed Triggered Text is displayed at
the lower part of the screen and the text is entered from here. To enter a control code, first put an up-arrow then put a two-
digit HEX code, e.g., to put a HEX code 01H, program in 01.

SET TRIGGERED TEXT

Set Triggered Text can be used as an alarm input to trigger a corresponding programmed alarm. You can select RTS as
a triggering source of any of the 16 alarms.

Figure 43: SET TRIGGERED TEXT Sub-Menu

DISPLAY TEXT

OFF

OUTPUT TEXT

OFF

SET TRIGGERED TEXT
EXIT

EXIT

Press the “Up” or “Down” button to move the cursor to “EXIT” and press “Set” to return to the previous menu.

DISPLAY TEXT

OFF

OUTPUT TEXT

OFF

SET TRIGGERED TEXT
EXIT

Figure 42: TRIGGERED TEXT Sub-Menu

TRIGGERED TEXT

Triggered Text is a data string that associates with one of the 16 alarms. When the alarm is triggered by a source, the
associated string is sent out and/or displayed if enabled respectively. Each Triggered Text can contain up to 40 printable
ASCII data. If non-printable data (control code) is included, each control code occupies 3 printable spaces. Therefore
only 13 control codes maximum can be programmed in one Triggered Text program control escape etc.

DISPLAY TEXT

Choices: ON, OFF

OUTPUT TEXT

Choices: ON, OFF

Advertising