Data dump connections appendix a – AVE Video Serial Synchronous ATM Interface VSSI-PRO User Manual

Page 49

Advertising
background image

49

PERFORMING A DATA DUMP

1. Make the proper connections as shown.
2. Make sure the PORT 1 communication settings are the same as the computer’s settings.
3. Run a PORT A receiving test (access PORT A submenu in TEST/DEMO of the main programming menu) to make
sure data is being received.
4. Go to DUMP DATA in the PORT A submenu and press “Set”. The data should appear on the computer screen. Save
this data to a file.

Follow the same procedure for performing a data dump from PORT B using the PORT B sub-menu for a receiving test and
the DUMP DATA command.

Figure 1A: Data Dump Connections

DATA DUMP CONNECTIONS

To execute a data dump you will have to connect wires from the DB-9 connector of the VSSI-Pro to either Com 1 or
Com 2 of a computer, using the following pin-out diagram:

Table 1A: Data Dump Connections

DATA DUMP CONNECTIONS

APPENDIX A

VSSI-Pro VIDEO SERIAL ATM INTERFACE

SDLC / BISYNC CAMERA PORT / JOURNAL / TCPIP

Com 1 (DB-9) Com 2 (DB-25)

3

8

2

3

5

5

5

7

MODEM

VSSI-PRO

DB-9 Connec-
tor

COM 1 (DB-9)
COM 2 (DB-25)

ATM

CAMERA

MONITOR

RG-59U

RG-59U

DB-9 Connec-
tor

Triport