E L E C T R I C A L

I N S T A L L A T I O N

This appliance must be branch circuit protected with

proper ampacities, in accordance with the wiring

diagram. The Quickchiller must be properly

grounded in accordance with the National Electrical

Code and applicable local codes. Wire size for the

main incoming power to the unit must match the

minimum size listed in the specifications applicable

to the specific Quickchiller model. For supply

connections, locate the wire size listed in this manual.
Before operating the chiller, check all cable connections

in the electrical connection area for tightness since

connections can loosen during transport.

N O T E :

After electrical connections have been

completed, operate the appliance in any

chilling mode for a period of 15 minutes

and recheck the main power connections at

the terminal block to make certain they

remain tight.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.

D A N G E R

ELECTRICAL CONNECTIONS MUST

BE MADE BY A QUALIFIED SERVICE

TECHNICIAN IN ACCORDANCE WITH

APPLICABLE ELECTRICAL CODES.

VOLTAGE

PHASE CYCLE

/

HZ

Q C - 3

Q C - 2 0

Q C - 4 0

Q C - 5 0

Q C - 1 0 0

S E L F - C O N TA I N E D

208-240VAC 1 ph 50/60 Hz

R

ECOMMENDED CIRCUIT AMPERAGE

:

R

ECOMMENDED WIRE SIZE

:

20 amps

12/2 w.g.

20 amps

12/2 w.g.

30 amps

10/2 w.g.

40 amps

8/2 w.g.

60 amps

6/2 w.g.

N O C O R D A N D P L U G

VOLTAGE

PHASE CYCLE

/

HZ

Q C - 3

Q C - 2 0

Q C - 4 0

Q C - 5 0

Q C - 1 0 0

S E L F - C O N TA I N E D

208-240VAC 3 ph 50/60 Hz

R

ECOMMENDED CIRCUIT AMPERAGE

:

R

ECOMMENDED WIRE SIZE

:

NOT AVAILABLE

NOT AVAILABLE

NOT AVAILABLE

20 amps

12/3 w.g.

40 amps

8/3 w.g.

380-415VAC 3 ph 50/60 Hz

R

ECOMMENDED CIRCUIT AMPERAGE

:

R

ECOMMENDED WIRE SIZE

:

NOT AVAILABLE

NOT AVAILABLE

30 amps

10/2 w.g.

NOT AVAILABLE

30 amps

10/2 w.g.

N O C O R D A N D P L U G

VOLTAGE

PHASE CYCLE

/

HZ

Q C - 3

Q C - 2 0

Q C - 4 0

Q C - 5 0

Q C - 1 0 0

R E M O T E C O M P R E S S O R
( C a b i n e t O n l y )

208-240VAC 1 ph 50/60 Hz

R

ECOMMENDED CIRCUIT AMPERAGE

:

R

ECOMMENDED WIRE SIZE

:

NOT AVAILABLE

NOT AVAILABLE

NOT AVAILABLE

20 amps

12/2 w.g.

30 amps

10/2 w.g.

N O C O R D A N D P L U G

E L E C T R I C A L S P E C I F I C AT I O N S

Wire diagrams are located near the top of the unit, close to the compressor or control panel.

Advertising