Alto-Shaam QuickChiller QC-50 User Manual

Page 5

Advertising
background image

C L E A R A N C E R E Q U I R E M E N T S

BACK: 6" (152mm)

TOP: 6" (152mm)

SIDES: 4" (102mm) minimum at both sides.

18" (457mm)

MINIMUM CLEARANCE

FROM HEAT PRODUCING EQUIPMENT

.

I N S TA L L AT I O N R E Q U I R E M E N T S

Unit must NOT be tipped on its side

at any time.

Tipping will cause damage to the unit

and void the warranty.

One (1) Floor Drain: 1/2" (12,7mm) diameter

— Appliance must be installed level.
— The appliance must not be installed in any area

where it may be affected by steam, grease, dripping
water, extreme temperatures, or any other severely
adverse conditions.

In order to maintain standards established by the
National Sanitation Foundation, all counter mounted
equipment must be sealed to the counter with a NSF
listed silicone sealant.

C A U T I O N

TO PREVENT PERSONAL INJURY,

USE CAUTION WHEN MOVING OR

LEVELING THIS APPLIANCE.

5-Year Limited

Warranty on

self-contained

compressor

Effective from date of

shipment. (

EXCLUDES LABOR

)

Position the Quickchiller

to allow sufficient air

ventilation through the

condensing unit(s). The

rear of unit should be no

closer than 6" (152mm)

to any wall or structure.

Avoid installing the

chiller immediately

adjacent to fryers,

charbroilers, or any other

equipment producing

grease laden air; heat

producing equipment

such as ovens and

ranges; and steam discharging equipment such as

steamer ovens and kettles. Do not locate the

Quickchiller in direct sunlight.
Allow sufficient front clearance for serviceability

and for easy maneuvering of food trolleys in and

out of the cabinet.

I N S TA L L AT I O N

Prior to moving the Quickchiller to the installation

site, check the dimensions of doors, passageways, and

ceiling heights in the areas through which the cabinet

must be moved. Also check the turning radius if the

cabinet must be moved around an existing structure.

The use of a fork lift or pallet lift truck is required for

moving and leveling most Quickchiller models.

NOTE

: In certain instances, it may be necessary to

remove doors and door hardware to

negotiate tight spaces.

®

D A N G E R

IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH,
OR CAUSE PROPERTY DAMAGE.

READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.

I N S T A L L A T I O N

S I T E I N S T A L L A T I O N

Q U I C K C H I L L E R • I N S TA L L AT I O N / O P E R AT I O N / S E R V I C E M A N U A L • 3 .

Advertising