Q U I C K C H I L L E R • I N S TA L L AT I O N / O P E R AT I O N / S E R V I C E M A N U A L • 2 1 .

S U B T I T L E

T I T L E

USER SETTINGS

CHANGING USER SETTINGS

Starting from the

OFF

position, press the power key

ON

. The Alto-Shaam name will illuminate and the

SELECTION SCREEN

will appear on the display.

The compressor will become energized and will

begin to operate if required by the sensors.
Press the PROGRAM key. The display will indicate

the User Settings each time the Program key is

pressed.

z

Press the up

or down arrow keys to select the desired

User Setting.
Press the right or left arrow keys to change the value.

Press the PROGRAM key to save settings and

return to the SELECTION SCREEN.

PROGRAMMING USER SETTINGS

1. START MANUAL DEFROST

Select Start Manual Defrost and press the
START/STOP

key to initiate a manual defrost

cycle. The defrost cycle will complete operation

when the temperature of the coil or coils reach set-

point values or after a period of 20 minutes,

whichever occurs first.

2. DEFROST FREQUENCY

The display will indicate the length of time necessary

to accrue before the Fan Timer triggers an automatic

defrost cycle. This period of time can be adjusted by

pressing the right or left arrow keys to to increase

or decrease automatic defrost cycle time (4-10 hours).

3. LANGUAGE

The display will indicate the currently selected

language. Press the right or left arrow key to select

English, Spanish, or French as the language of choice.

4. DATE

The display will indicate YEAR, MONTH, and DAY OF

MONTH (YYYY/MM/DD). Press the up or down

arrow key to select the date, time, and day, and the

right or left arrow key to increase or decrease the

numbers as required.

5. TIME

The display will indicate the current TIME of day

(HH:MM). Press the up or down arrow key to select

the hours or minutes and the right or left arrow key

to increase or decrease the numbers as required.

6. °F/°C - Fahrenheit/Celsius

The display will indicate a choice between Celsius and

Fahrenheit for Quickchiller temperature display

readings. Press the right or left arrow key to

toggle the setting.

7. HOLD DEFAULT

The display will indicate the default HOLD

temperature. Press the right or left arrow key to

increase or decrease the default holding temperature

between a range of -5°F to +40°F (-21°C to +4°C).

8. HACCP ADDRESS

The display will indicate the HACCP Address

Number. This item allows the operator to assign a

specific identifying number (1 to 247) to the individual

Quickchiller as part of a serial communication interface

for the web-based, HACCP with Kitchen Management

software package option. Press the right or

left arrow key to increase or decrease the number.

9. PROBE VERIFICATION

With the probe verification selected, press the Start key

to enter the probe verification mode.

The display will show the offset and the temperature of:

Top Probe (

WHERE APPLICABLE

)

Middle Probe (

WHERE APPLICABLE

)

Bottom Probe (

WHERE APPLICABLE

)

If probe calibration is needed, place the probe in a

glass of ice-water and let the probe settle in

temperature. The temperature in the glass should be

32°F (0°C).
To calibrate, Press up or down arrow key to adjust

between the probes, and the right or left arrow

keys to adjust the calibration value.

Press the PROGRAM key to exit probe

calibration mode.

10. PRESETS

(0=

UNLOCKED

, 1=

LOCKED

)

If the presets are locked, pressing

START

on

the desired preset will skip the mode overview

and will start immediately. Factory default

is

LOCKED

.

11. CHILL MODES

(0=

UNLOCKED

, 1=

LOCKED

)

If the chill modes are locked, pressing the

chill mode button will skip the mode overview

and will start immediately. Factory default

is

UNLOCKED

.

12. FACTORY RESET

Resets all presets and user-defined settings to factory

default settings. Warning: Pressing Factory Reset will

erase all User Settings and Presets programmed by the

user. All custom User Settings and Presets will need to

be reprogrammed.

A D V A N C E D O P E R A T I O N

O P E R A T I O N

USER SETTINGS

1.

Start Manual Defrost

7.

Default Hold Temperature

2.

Defrost Frequency

8.

HACCP Address

3.

Language

9.

Probe Verification

4.

Date - YYYY/MM/DD

10.

Presets

5.

Time - HH:MM

11.

Chill Modes

6.

°F/°C - Fahrenheit/Celsius 12. Factory Reset