Installation, Gas connection (xr8-g only) – Blodgett XR8-E User Manual

Page 11

Advertising
background image

9

Installation

Gas Connection (XR8-G only)

PRESSURE REGULATION AND TESTING
XR8-G ovens are rated at 110,000 BTU/Hr. (32 kW) (116

MJ/hr). Each oven has been adjusted at the factory to

operate with the type of gas specified on the rating plate.

INLET PRESSURE

Natural

Propane

Min

Max

Min

Max

W.C.

6.0

14.0

11.0

14.0

kPa

1.2

3.5

2.7

3.5

MANIFOLD PRESSURE

Natural

Propane

W.C.

3.5

10.0

kPa

.87

2.5

• Inlet Pressure - the pressure of the gas before it

reaches the oven.

• Manifold Pressure - the pressure of the gas as it

enters the main burner(s).

• Min - the minimum pressure recommended to oper-

ate the oven.

• Max - the maximum pressure at which the manufac-

turer warrants the oven’s operation.

Each oven is supplied with a regulator to maintain the

proper gas pressure. The regulator is essential to the

proper operation of the oven and should not be removed.

It is preset to provide the oven with 3.5” W.C. (.87 kPa)

for natural gas and 10.0” W.C. (2.5 kPa) for Propane at

the manifold.
DO NOT INSTALL AN ADDITIONAL REGULATOR

WHERE THE OVEN CONNECTS TO THE GAS SUPPLY

UNLESS THE INLET PRESSURE IS ABOVE MAXIMUM.
Prior to connecting the oven, gas lines should be thor-

oughly purged of all metal filings, shavings, pipe dope,

and other debris. After connection, the oven should be

checked for correct gas pressure.
The oven and its individual shutoff valve must be discon-

nected from the gas supply piping system during any

pressure testing of that system at test pressures in ex-

cess of 1/2 psig (3.45kPa).
The oven must be isolated from the gas supply piping

system by closing its individual manual shutoff valve dur-

ing any pressure testing of the gas piping system at test

pressures equal or less than 1/2 psig (3.45kPa).

Figure 4

Gas Connection

2.78” (71 mm)

Gas Connection

37.83” (961 mm)

Side View with Stand

Advertising
This manual is related to the following products: