Installation, Ventilation (xr8-g only) – Blodgett XR8-E User Manual

Page 8

Advertising
background image

6

Installation

Ventilation (XR8-G only)

Direct Flue Arrangement
When the installation of a mechanically driven exhaust

hood is impractical the oven may be vented by a direct

flue arrangement.

WARNING!!

It is essential that the direct flue be installed

as follows. Incorrect installation will result in

unsatisfactory baking and oven damage.

The flue must be 6” (15 cm) diameter, class B or better.

The height of the flue should be compliant with the cur-

rent revision of NFPA 54, Ansi Z223.1. Never direct vent

the oven into a hood. The flue should be capped with a

UL Listed type vent cap to isolate the unit from external

environmental conditions.
The direct vent cannot replace air consumed and vented

by the oven. Provisions must be made to supply the room

with sufficient make-up air. Total make-up air require-

ments for each oven section should be approximately 35

CFM (.99 m3/min). To increase the supply air entering the

room, a ventilation expert should be consulted.

Installing the draft hood
Ovens ordered for direct venting are supplied with a draft

hood. Install the draft hood as follows:
1. Disconnect power to the oven.
2. Remove the two screws holding the exhaust guard.

See Figure 2.

3. Install the draft hood using the screws removed in

step 2. See Figure 3.

4. Reconnect power to the oven.

Figure 2

Figure 3

Advertising