Vertical contact toaster, Operation (continued), Hi-limit reset button – A.J. Antunes & Co VCT-2000 9210212 User Manual
Page 10
VERTICAL CONTACT TOASTER
10
P/N 1010875 Rev. C 02/13
Hi-Limit Reset Button
A Hi-Limit Control turns off electrical power to the heat-
er and control circuits if the Platen overheats. To reset
the control, allow sufficient time (10-15 minutes) for the
unit to cool, then locate the Reset Button at the rear of
the unit. Remove the black protective cap, press the
Reset Button, and reinstall the protective cap (Figure
2).
NOTE: If the unit requires continuous resetting,
contact your Authorized Service Agency.
TEMP
UP
TEMP
DOWN
TEMP
SCALE
°F
°C
POWER
551
Figure 5. Platen Heater Setpoint Temperature
1. Press the
TEMP UP and TEMP
DOWN buttons at the same time
for 1 second to start adjustment
sequence.
2. Press
TEMP UP button to
raise Platen Heater setpoint
temperature.
3. Press
TEMP DOWN button
to lower Platen Heater setpoint
temperature.
TEMP
UP
TEMP
DOWN
TEMP
SCALE
°F
°C
POWER
336
Figure 6. Auxiliary Air Heaters Setpoint Temperature
1. Press the
TEMP UP and TEMP
SCALE buttons at the same time
for 1 second to start adjustment
sequence.
2. Press
TEMP UP button to raise
Auxiliary Air Heaters setpoint
temperature.
3. Press
TEMP DOWN button to
lower Auxiliary Air Heaters
setpoint temperature.
OPERATION (continued)