Vertical contact toaster, Sp - p 600, 400 sp - a – A.J. Antunes & Co VCT-2000 9210212 User Manual

Page 9: Lo use, Operation (continued), Temperature control panel

Advertising
background image

9

VERTICAL CONTACT TOASTER

P/N 1010875 Rev. C 02/13

Temperature control panel

NOTE: The term “setpoint temperature” refers to

the desired temperature setting.
To display the actual Platen temperature—providing it

is over 440°F (227°C)—press the

TEMP UP button.

To display the actual Auxiliary Air Heater temperature—

providing it is over 360°F (182°C)—press the

TEMP

DOWN button.
To switch the temperature display between Fahrenheit

(°F) and Celsius (°C), press and hold the

TEMP

SCALE button for 5 seconds.

PLATEN HEATER TEMPERATURE ADJUSTMENT

1. Turn the Rocker Switch on and wait for the

Temperature Display to finish the power-up

sequence (Figure 4).

2. Press and hold both

TEMP UP and TEMP DOWN

buttons for over 1 second until the display flashes

the Platen setpoint temperature, then release

(Figure 5).

3. Press the

TEMP UP button to raise the setpoint

temperature or press the

TEMP DOWN button to

lower the setpoint temperature.

NOTE: The Maximum Platen Setpoint Temperature

is 600°F (315°C). If no change in temperature is

made within 5 seconds, the display reverts back to

the previous setpoint.
4. Release the button when the desired setpoint is

displayed.

AUXILIARY AIR HEATER TEMPERATURE ADJUSTMENT

1. Turn the Rocker Switch on and wait for the

Temperature Display to finish the power-up

sequence (Figure 4).

2. Press and hold both

TEMP UP and TEMP

SCALE buttons for over 1 second until the

display flashes the setpoint temperature, then

release (Figure 6).

3. Press the

TEMP UP button to raise the setpoint

temperature or press the

TEMP DOWN button to

lower the setpoint temperature.

NOTE: The maximum Auxiliary Air Heater Setpoint

Temperature is 400°F (204°C).
4. Release the button when the desired setpoint is

displayed.

NOTE: If no change in temperature is made within

5 seconds, the display reverts back to the previous

setpoint.

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

SP - P

600

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

400

SP - A

Figure 4. Temperature Power Up Sequence

3. “SP-A” (Setpoint Auxiliary)

is displayed.

1. “SP-P” (Setpoint Platen)

is displayed.

“Heat On” LED will blink on/off during warm-up and when either

platen or auxiliary air heaters are calling for heat.

2. Current Platen Setpoint

Temperature setting is shown.

4. Current Auxiliary Air Setpoint

Temperature is shown.

5. “LO” is displayed until

platen temperature rises

above 550°F (288°C).

6. USE is displayed when

Platen Setpoint Temperature*

is reached

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

LO

USE

* Platen setpoint temperature

must be between 460°F (238°C)

and 600°F (315°C).

OPERATION (continued)

Advertising