8 Specifications

8.1

Read Distance

using PROXCARD II®

¾ Over all Operating Limits, minimum (@12VDC))

5.0 inches (12.7 cm)

¾ Non-Metallic Mounting, typical (@12VDC)

8.0 inches (20.3 cm)

¾ Mounted on Metal, typical (@12VDC)

5.5 inches (14 cm)

¾ Overall Operating Limits, minimum (@24VDC)

5.5 inches (14 cm)

¾ Non-Metallic Mounting, typical (@24VDC)

9.0 inches (23 cm)

¾ Mounted on Metal, typical (@24VDC)

6.0 inches (15.2 cm)

8.2

Environmental Characteristics

¾ Designed for listing under UL 294 “Standard for Access Control System Units”
¾ Operating Temperature Range

-30

o

C to 65

o

C (-22

o

F to 150

o

F)

¾ Storage Temperature Range

-40

o

C to 85

o

C (-40

o

F to 185

o

F)

¾ Operating Humidity Range

5% to 95% non-condensing

¾ Operating Vibration Limit

.04 g

2

/Hz 20-2000Hz

¾ Operating Shock Limit

30g, 11mS, Half Sine

¾ Enclosure Material

UL Recognized Lexan® Polycarbonate

¾ Weight 11.3oz

(310gms)

8.3

Power Requirements

¾ Power supply

Linear type recommended

¾ Operating Voltage Range (+DC)

10VDC -28.5VDC

¾ Maximum Average Current 12V/24V

90mA/155mA

¾ Transient Protection (all terminals)

UL 294

¾ Reverse Voltage Protection

YES

¾ Input Voltage (maximum data-0/1 lines)

28.5VDC

¾ Input Voltage (maximum interface lines)

28.5VDC

8.4

Option D – Buffered Direct Connect Keypad

¾ Operating Voltage Range (+DC)

10VDC -26VDC

¾ Input Voltage (Maximum Data – 0/1 Lines)

14VDC

¾ Input Voltage (Maximum Interface Lines)

14VDC

8.5

Operating Parameters

¾ Excitation Frequency

125KHz

¾ Duty Cycle (alternate power level rate)

20% @ 60mS period

¾ Read and Report Speed (26 bit Wiegand Card)

175mS

¾ Maximum Cable Distance to Host

500 feet (152 meters)

¾ LED Type

Bi-colored Red/Green

¾ LED Operation (host control of red/green)

<

.5V on LED control line

¾ Beeper Operation (host control)

<

.5V on beeper line

¾ LED Control (default)

internal/single

¾ Beeper Control (default)

Beeper enabled

¾ Anti-Pass Back Delay (default)

1 second

¾ Wiegand Data Pulse Widths (default)

40uS

¾ Wiegand Data Interval (default)

2mS