3 wiring, 1 standard wire connections, 2 buffered direct wire connections – option d – HID ProxPro Installation Guide User Manual

Page 5: 3 direct wire connections – option s, Wiring, Standard wire connections, Buffered direct wire connections – option d, Direct wire connections – option s

Advertising
background image

ProxPro

®

Installation Guide

Part No. 5355-900, Rev N.1

3 Wiring

3.1 Standard Wire Connections

TB1

1

2

3

4

5

6

7

8

9

10

11

+DC Ground

Data0/

Data

Data1/
Clock

Shield
Ground

Green

LED

Red

LED

Beeper Hold/

Card
Present

Tamper

Common

Tamper
Select

Red Black

Green

White

Violet

Orange

Brown

Yellow

Blue --

--

3.2 Buffered Direct Wire Connections – Option D

10

11

E1

E2

E3

E4

E5

E6

E7

E8

E9

E10

Tamper
Common

Tamper
Select

+DC

Ground

Row 1

Row 2

Row 3

Row 4

Column
1

Column
2

Column
3

Select
Low

Red /
Black

Red /
Green

White /
Red

White /
Black

Gray Violet Red

/

Yellow

Pink Tan White

/

Blue

White /
Green

White /
Yellow

3.3

Direct Wire Connections – Option S

TB2

1

2

3

4

5

6

7

Row 1

Row 2

Row 3

Row 4

Column 3

Column 2

Column 1

Red Black

Green

White

Drain Orange

Brown

Notes:

1. When

using

5 conductor cable, the power supply and Host must have a common ground (voltage

reference).

2. 6 conductor cable is required when controlling the red and green LED. (Alpha 1296 C or

equivalent)

3. 7 conductor cable is required when both green and red LED’s are controlled by the Host and the

power supply and Host "ground" are separate. (Alpha 1297 C or equivalent)

4. A 22 AWG twisted pair, shielded, stranded cable is often required for the tamper switch. Follow the

recommendations of the manufacturer of the Host system. If the tamper input is a supervised input
the "end of line" resistors may be mounted in the enclosure. Use extreme care and shield any bare
wire from the printed circuit assembly and its components.

5. The inner diameter of the cable fitting will accommodate a cable with an outer diameter of .300

inches (nominally).

6. Connect cable shield by connecting drain wire to TB1-2 ground. Leave foil and drain wire

disconnected at host end of cable by cutting them off at the end of the cable jacket.

7. When using the Buffered Direct Connect ProxPro with a 20 conductor cable, DC+ and Power (Red

and White / Red wires) must have a common connection to the host +DC power supply. The two
ground wires (Black and White / Black) must have a common ground connection to the host +DC
power supply.

February 22, 2007