4.2 Switch 1-2 Audible Tone Control

The Audible Tone (Beeper) may be enabled or disabled to sound when an access card is read. When
enabled, the audible tone is sounded when a card is successfully read. When the Beeper is disabled,
the only method to activate the Beeper is to use the external Beeper control line. The Beeper will turn
on when the control line is switched to ground. Switch 2 in the "on" position enables the audible tone
(the default).

4.3 Switch 1-3 Green LED Control

The Green LED can be configured to turn on, or not turn on when an access card is read. Switch 3 in
the “off” position selects the Green LED to be turned on (the default).

4.4 Switch 1-4 Keypad Operation

The keypad inputs may be processed by the reader or may be connected directly to the Host. When
the keypad inputs are processed by the reader, the reader scans the keypad and outputs the keypad
entries over the "Wiegand" interface. When the keypad is connected to the Host, the Host determines
which key is being entered. Switch 4 is in the "on" position for the default mode (the keypad inputs are
processed by the reader).

4.5 Switch 1-5 Single / Dual LED Control

In Single LED Control the LED is Red. When an access card is read, the LED toggles Green, and then
back to Red. Grounding the Green LED Control line will change the LED from Red to Green. The
reader maybe configured so the Green LED is externally controlled independently from the Red LED.
This is referred to as Dual LED Control. When the Red or Green LED Control line is switched to
ground, the respective LED is turned on. If both LED’s are on, the LED appears to glow amber.
Switch 5 in the “off” position selects Single LED Control (the default).

4.6

Switch 1-6 and 1-7 Data Output Biasing

The data outputs may be configured as open collector or biased at 5VDC through 1k Ohm resistors by
the reader. The default (standard) configuration is output biasing, with switches 6 and 7 "on" .

Note: When the outputs are configured as open collector, the host panel should provide bias voltage at
the panel inputs.

KeyPad

Beeper Control
Hardware Identity

on

Default Setting

on
on

on

on
on

on

off

(The keypad data is sent on data lines), N/A for D version

(Identifies the unit to be "Wiegand")

1 2 3 4 5 6 7 8

Single/Dual LED CNTL

(Single Line LED Control)

off

Green LED Control

Not used

(The Wiegand data outputs are pulled up to +5VDC

through a 1kOhm resistor)

(The green LED is enabled when a card is read)

( The beeper is enabled when a card is read)

Wiegand Data 0 Bias
Wiegand Data 1 Bias

Notes:

This section of this document describes the keypad interface. The keypad has twelve keys, four rows
by three columns. The characters 0 to 9, # and * are arranged the same as a standard telephone
keypad. There are two methods for interfacing to the Keypad.

February 22, 2007