Logical drive, Hot swap, Scsi drive states – American Megatrends MegaRAID Express 500 User Manual

Page 29: Logical drive states

Advertising
background image

Chapter 2 Introduction to RAID

15

Logical Drive

A logical drive is a partition in a physical array of disks that is made up of
contiguous data segments on the physical disks. A logical drive can consist of:

an entire physical array

more than one entire physical array

a part of an array

parts of more than one array, or

a combination of any two of the above conditions

Hot Swap

A hot swap is the manual replacement of a defective physical disk unit while the
computer is still running. When a new drive has been installed, you must issue a
command to rebuild the drive.

SCSI Drive States

A SCSI disk drive can be in one of these states:

State

Description

Online

(ONLIN)

The drive is functioning normally and is a part of a configured logical
drive.

Ready

(READY)

The drive is functioning normally but is not part of a configured logical
drive and is not designated as a hot spare.

Hot Spare

(HOTSP)

The drive is powered up and ready for use as a spare in case an online
drive fails.

Fail

(FAIL)

A fault has occurred in the drive placing it out of service.

Rebuild

(REB)

The drive is being rebuilt with data from a failed drive.

Logical Drive States

State

Description

Optimal

The drive operating condition is good. All configured drives are online

Degraded

The drive operating condition is not optimal. One of the configured drives
has failed or is offline.

Failed

The drive has failed.

Offline

The drive is not available to MegaRAID Express 500.