Dos aspi driver error messages – American Megatrends MegaRAID Express 500 User Manual

Page 90

Advertising
background image

MegaRAID Express 500 Hardware Guide

76

DOS ASPI Driver Error Messages

Message

Corrective Action

American Megatrends Inc.
ASPI Manager has NOT
been loaded.

The ASPI manager is not loaded. One of the failure
codes listed below is displayed next.

Controller setup FAILED
error code=[0xab]

Correct the condition that caused the failure. The failure
codes are:

0x40

No MegaRAID adapters found

0x80

Timed out waiting for interrupt to be posted

0x81

Timed out waiting for MegaRAID Express
500 Response command.

0x82

Invalid command completion count.

0x83

Invalid completion status received.

0x84

Invalid command ID received.

0x85

No MegaRAID Express adapters found or no
PCI BIOS support.

0x90

Unknown Setup completion error

No non-disk devices were
located

The driver did not find any non-hard drive devices
during scanning. A SCSI device that is not a hard disk
drive, such as a tape drive or CD-ROM drive, must be
attached to this SCSI channel. The SCSI ID must be
unique for each adapter and cannot be SCSI ID 0. The
supported SCSI IDs are 1, 2, 3, 4, 5, and 6.

'ERROR: VDS support is
*INACTIVE* for
MegaRAID Express logical
drives

The /h option is appended to driver in

CONFIG.SYS or this driver is used with a BIOS that is

earlier than v1.10, or no logical drives are configured.

Advertising