American Megatrends MegaRAID Express 500 User Manual

Page 88

Advertising
background image

MegaRAID Express 500 Hardware Guide

74

Message

Problem

Suggested Solution

1 Logical Drive Degraded

A logical drive signed on
in a degraded state.

Make sure all physical
drives are properly
connected and are powered
on.

Run MegaRAID Manager
to find out if any physical
drives are not responding.
Reconnect, replace, or
rebuild any drive that is
not responding.

Insufficient memory to
run BIOS. Press any key
to continue…

Not enough MegaRAID
Express 500 memory to
run MegaRAID BIOS.

Make sure MegaRAID
Express 500 memory has
been properly installed.

Insufficient Memory

Not enough memory on
the MegaRAID Express
adapter to support the
current configuration.

Make sure MegaRAID
Express memory has been
properly installed.

The following SCSI IDs
are not responding:
Channel x:a.b.c

The physical drives with
SCSIO IDs a, b, and c are
not responding on SCSI
channel x.

Make sure the physical
drives are properly
connected and are powered
on.

Advertising