Device Identification on MegaRAID Express 500

All logical drives on each SCSI bus are identified to the host as ID 0.
Differentiate the drives with Logical Unit Identifiers (LUNs). ID 0 cannot be
used for non-disk devices because they are limited to IDs 1 through 6. The
MegaRAID Express 500 is limited to eight logical drives because LUNs are used
to present logical drives. The SCSI-2 ANSI specification has a limit of eight
LUNs per ID. The SCSI-3 specification increased the number of LUNs to 16. An
example of ID mapping follows.

Example of MegaRAID Express 500 ID Mapping

ID

Channel 1

0

A1-1

1

A2-1

2

CD

3

A2-5

4

CD

5

A4-1

6

Optical

7

Reserved

8

A5-2

9

A5-6

10

A6-1

11

A6-4

12

A6-7

13

A7-2

14

A7-5

15

A7-8

As Presented to the Operating System

ID

LUN

Device

ID

LUN

Device

0

0

Disk (A1-X)

1

0

Scanner

0

1

Disk (A2-X)

2

0

CD

0

2

Disk (A3-X)

3

0

Tape

0

3

Disk (A4-X)

4

0

CD

0

4

Disk (A5-X)

5

0

Tape

0

5

Disk (A6-X)

6

0

Optical

0

6

Disk (A7-X)

0