2 master interfaces – ARM AMBA NIC-301 User Manual

Page 23

Advertising
background image

Functional Description

ARM DDI 0397G

Copyright © 2006-2010 ARM. All rights reserved.

2-8

ID031010

Non-Confidential

Timing isolation:

from the external master

from the network.

2.2.2

Master interfaces

The AMBA Network Interconnect supports the following master interfaces:

AXI master interfaces

AHB master interfaces on page 2-9

APB master interfaces on page 2-10.

AXI master interfaces

The network supports the full AXI protocol using an AXI master interface.

Configuration options

You can configure the following AXI options:

Address width of 32-64 bits.

Data width of 32, 64, 128, or 256 bits.

Data width upsize function that Upsizing data width function on page 2-12 describes.

User sideband signal width of 0-32 bits.

Data width downsize function that Downsizing data width function on page 2-14
describes.

Frequency domain crossing of type:

ASYNC

SYNC 1:1

SYNC 1:n

SYNC n:1

SYNC n:m.

Support for the full AXI protocol.

Note

You can reduce the gate count and increase the performance if all attached master that can
access the master interface does not create any AXI lock transactions.

Write issuing capability of 1-32 transactions.

Read issuing capability of 1-32 transactions.

Buffering that FIFO and clocking function on page 2-15 describes.

Timing isolation:

from the external slave

from the network.