Alloy Computer Products POEGEM12T2SFP User Manual

Page 202

Advertising
background image

POEGEM12T2SFP User Manual

198

Alloy Computer Products Pty Ltd Copyright ©2006

set txPeriod

Syntax:

set txPeriod <port-range> <sec>

Description:

A timer used by the Authenticator PAE state machine to determine when an EAPOL PDU is to be
transmitted.

Argument:

<port range>: syntax 1, 5-7, available from 1 to 12

<sec>: timer , range 1-65535

Possible value:

<port range>: 1 to 12

<sec>: 1-65535, default is 30

Example:

POEGEM12T2SFP(802.1x)# set txPeriod 2 30

: Sets the timer for port 2 to 30 seconds.

set quiet-period

Syntax:

set quiet-period <port-range> <sec>

Description:

A timer used by the Authenticator state machine to define periods of time when it will not attempt
to acquire a Supplicant.

Argument:

<port range> : syntax 1,5-7, available from 1 to 12

<sec> : timer , range 0-65535

Possible value:

<port range> : 1 to 12

<sec> : 0-65535, default is 60

Example:

GS-2116C(802.1x)# set quiet-period 2 30

: Sets the quiet period for port 2 to 30 seconds.

Advertising