3 atto fibrecenter 3400 characteristics, Specifications, Local and network management – ATTO Technology 3400 User Manual

Page 10: Features, 3 atto fibrecenter 3400 characteristics

Advertising
background image

5 ATTO FibreCenter 3400

Ins

tallation and Operation Manual

3 ATTO FibreCenter 3400 characteristics

ATTO FibreCenter 3400 is a 2-Gigabit Fibre Channel hub configured with eight (8) Fibre Channel ports
and an Ethernet management port. The FibreCenter 3400 is designed to integrate industry leading
performance and Storage Area Network (SAN) capabilities into mid-range applications by providing a
high-speed, central connection point for Fibre Channel connections.

The FibreCenter 3400 Fibre Channel rack system
design provides maximum dependable
performance for high availability systems through
a hot-swappable, dual power module.

The FibreCenter 3400 module is housed in one
module bay of a dual module, 1U high, industry
standard rack enclosure complete with mounting
brackets. Using two modules in a rack provides a
maximum port density of 16 SFP ports and
redundant power and cooling in a full width 1U
rack.

The unit may be configured as one 8-port hub
(Zone 1) or two 4-port hubs (Zones 2 and 3).
When configured as Zones 2 and 3, the
FibreCenter allows each 4-port zone to run at
different speeds (1Gb or 2Gb). Configuration is
managed through a 10BaseT Ethernet port.

Specifications

❈Eight 2-Gigabit Fibre Channel ports with

Small Formfactor Pluggable (SFP) interface

❈400 MB/sec. maximum throughput in full

duplex mode per zone

❈Auto negotiation between 2-Gigabit and 1-

Gigabit modes

❈Port management interface for “on-the-fly”

configuration

❈Ethernet configuration, management and

monitoring

❈Modular design for maximum data reliability,

availability and serviceability.

❈Support for Fibre Channel Class 2, Class 3

and Intermix specifications

❈ Support for full-duplex data transfers

❈ Full Fibre Channel support for FC-P2, PLDA

and public loop login

❈32 MB of SDRAM memory for code

execution and Ethernet packets.

❈4 MB of flash memory, field upgradable

through Ethernet, for code and parameter
storage.

Local and network management

❈Command Line Interface provides local and

remote management and diagnostic support
using Telnet over Ethernet

❈Field upgradeable firmware using FTP

through the Ethernet port

Features

❈Digital retiming circuits eliminate jitter

transfer to downstream devices.

❈ Lockable port status

Disabled = Port is disconnected from FC
network.
Enabled = Port is connected to FC network
subject to automatic bypass criteria.

❈Automatic bypass may be disabled to allow

link to always remain connected.

❈ Link transmitter may be optionally disabled

when port is disabled.

Reduced power consumption.
No external monitoring of FC activity.

❈ All settings are persistent.

Advertising