2 diagnostic commands, Status, Telnet status – ATTO Technology 3400 User Manual

Page 21: Version, 2 diagnostic commands, Status telnet status version

Advertising
background image

Secure Data Path Applicationv 16

7.2 Diagnostic commands

The commands in this section only provide information about the ATTO FibreCenter 3400. Access this
information using these command line interface commands in a Telnet session over the Ethernet port.

Status

Displays the status of the power supplies and the cooling fans.

Limits:
PP = power supply status; OK = operating, NG=inoperable, NI = missing
FF = cooling fan status: OK = operating
K = L

Action: none

Information: get•Status•000

Return syntax: Status•000•PS1:PP•FAN1:FF•PS2:
PP•FAN2:FF•KEY:K

Return example:
Status•000•PS1:OK•FAN1:OK•PS2:OK•FAN2:OK•KEY:L

Telnet Status

Returns the Telnet status.

Limits: Status may be narrowed to [1] Telnet session information [2] TCP statistics or [3] Telnet auditing information

Action: none

Information: get•RACK •000•Telnet•Status• [1|2|3]

Version

Displays the firmware version of the rack. The FibreCenter 3400 has two processors. Returns reflect status of the ARM firmware and the Xilinx
firmware.

Limits: n = ARM firmware version; x = Xilinx firmware version

Action: none

Information: get•RACK •000•Version
Return: n.nn-xxx